PC5010 main
control panel - alarm only
-
PC5015 main
control panel - alarm plus Downlook video capability
-
support up to 32 zones using any combination of up to
:
|
- |
8 hardwire zones on main panel |
|
- |
8 hardwire zones using PC5108L video matrix module
(on PC5015 only) |
|
- |
4 general purpose hardwire zones and 2 waterflow
hardwire zones using PC5700 fire module
(in
Canada only) |
|
- |
24 hardwire zones using PC5108 eight zone expander
modules |
|
- |
8 keypad zones |
|
- |
32 wireless zones using PC5132 wireless receiver
module |
|
- |
all zones programmable as burglary or fire
|
|
- |
zone options include : Normally Closed loop, Single
End of Line (EOL) resistor, and Double EOL resistor *
*
keypad
zones cannot be programmed as fire zones and cannot support Double
EOL resistor supervision |
|
- |
27 programmable zone types, 8 programmable zone
options |
|
- |
supervised bell output - 700 mA @ 12VDC, PTC
protected, current limited at 3 A |
|
- |
steady, pulsed, temporal pattern, or strobe fire
output |
|
- |
additional supervised siren output is available
using PC5204 power supply module |
-
programmable voltage outputs
|
- |
1 high current 300mA PGM… can also be used for 2
wire smoke with a maximum of 20 detectors at 15mA per detector |
|
- |
1 low current 50mA PGM |
|
- |
8 additional low current PGM outputs using PC5208
module |
|
- |
4 additional high current PGM outputs using PC5204
module |
|
- |
24 programmable options |
-
local PCLINK™ and remote upload/download capability
|
- |
program system using DLS software and direct PC
connection to control panel or via remote PC over telephone line |
|
- |
view status and trouble conditions, and system 128
event buffer |
|
- |
remote access can be controlled by owner to prevent
unauthorized access to system |
|
- |
550mA @ 12.5VDC auxiliary power (400mA for UL
applications) |
|
- |
positive temperature coefficient (PTC) protected
battery, AUX, and Bell output |
|
- |
electronic protection of KEYBUS |
|
- |
supervision of AC power loss, low battery,
auxiliary power failure |
|
- |
internal clock locked to AC power frequency |
|
- |
supports all major formats including SIA & Contact
ID |
|
- |
supports LINKS1000™ cellular communications |
|
- |
supports LINKS2150™ and LINKS2450™ long range radio
communications |
|
- |
3 phone numbers (3rd backs up primary) |
|
- |
2 account numbers |
|
- |
DTMF or pulse dialing |
|
- |
DPDT line seizure |
|
- |
anti-jam feature |
|
- |
split reporting of selected events to each
telephone number |
|
- |
event initiated personal paging |
-
battery
required :
12V, 4 Ah, rechargeable sealed lead acid
-
transformer required :
16.5VAC, 40VA
|
|
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. |
|
|
|

System
Operation
· 2
system partitions… 2 account numbers
|
- |
each partition acts as a separate alarm system with
any number of zones, user codes, keypads and individually
programmable features |
· 38 - 4 or 6 digit access codes
|
- |
32 user codes, 1 system master code, 2 partition
master codes, 2 duress codes, and 1 maintenance code |
· automatic arming by partition
|
- |
each partition may be programmed to auto-arm at its
own time each day |
· keypad lockout
|
- |
panel can be programmed to lockout keypad if a
series of incorrect access code entries are made |
· 'quick arm' and 'quick exit'
|
- |
allows users to arm and exit easily |
· 'stay/away' zones and 'stay' arming
|
- |
security of perimeter arming while premise is
occupied |
· door chime
|
- |
programmable by zone |
|
- |
monitor a door by having keypad beep when the door
is opened and again when door is closed |
·
128
event buffer
|
- |
all events automatically stored with time and date
stamp to buffer |
|
- |
events can be printed on-site using the PC5400
serial printer interface module, viewed through an LCD Keypad, or
viewed and printed via PC using DLS software |

Full
Supervision
The system
continuously monitors the following trouble conditions :
-
AC power
failure
-
trouble by
zone
-
fire trouble
-
telephone
line trouble
-
low battery
-
bell output
trouble
-
loss of
internal clock
-
tamper by
zone
-
fail to
communicate
-
aux power
supply fault
-
module fault
(supervisory or tamper)
-
camera troubles
(on PC5015 with Downlook)

False Alarm
Prevention Features
-
audible exit
delay
-
audible exit
fault
-
quick exit
-
urgency on
entry delay
-
swinger
shutdown
-
cross zone
alarm
-
recent
closing transmission
-
burglary
verified timer *
-
double hit
timer *
-
communication
delay
-
rotating
keypress buffer
-
arm/disarm bell squawk
* on PC5015 v2.2x and higher
|
|